Especificaciones completas

MaxTester 715D - last-mile OTDR

Resumen
Fully featured, entry-level, dedicated OTDR with tablet-inspired design perfect for frontline singlemode fiber installers.
MaxTester 715D - last-mile OTDR

Características principales

  • Rugged, handy, lightweight, tablet-inspired design built for outside plant
  • 7-inch, outdoor-enhanced touchscreen—the biggest in the handheld industry
  • 12-hour autonomy
  • Dead zones: EDZ 0.9 m, ADZ 3.6 m
  • Dynamic range up to 32/30/30 dB
  • Swap-Out connector, replaceable whenever necessary for optimal performance over time without undue service cost and downtime

Aplicaciones

  • FTTx last-mile installation and troubleshooting
  • Short access-network testing
  • FTTA fiber-DAS installations
  • CATV/HFC network testing
  • FTTx Last-mile

Especificaciones

Technical specifications
Display7-in (178-mm) outdoor-enhanced touchscreen, 800 × 480 TFT
InterfacesTwo USB 2.0 ports
RJ45 LAN 10/100 Mbit/s
Storage2 GB internal memory (20 000 OTDR traces, typical)
BatteriesRechargeable lithium-polymer battery
12 hours of operation as per Telcordia (Bellcore) TR-NWT-001138
Power supplyPower supply AC/DC adapter, input 100-240 VAC, 50-60 Hz, 9-16 V DCIN 15 Watts minimum
Wavelength (nm)b1310 ± 30/1550 ± 30/1650 ± 15
Live wavelength (nm)1650
Isolation: 50 dB from 1265 nm to 1617 nm
Dynamic range (dB)c32/30/30
Event dead zone (m)d0.9
Attenuation dead zone (m)d3.6
Distance range (km)0.1 to 200
Pulse width (ns)3 to 20 000
Linearity (dB/dB)±0.05
Loss threshold (dB)0.01
Loss resolution (dB)0.001
Sampling resolution (m)0.04 to 5
Sampling pointsUp to 256 000
Distance uncertainty (m)e±(0.75 + 0.005 % × distance + sampling resolution)
Measurement timeUser-defined
Reflectance accuracy (dB)b±2
Typical real-time refresh (Hz)3
TECHNICAL SPECIFICATIONS (in-line PON power meter with OPM2 in option)b, i
Power range (dBm)–60 to 23
PON power meter (nm)Two channels: 1490/1550 and 1490/1577
Power uncertainty (dB)h, i±0.5
Calibrated wavelengths (nm)1310, 1490, 1550, 1625, 1650
Selectable wavelengths (nm)1310, 1490, 1550, 1577, 1625, 1650, 1490/1550, 1490/1577
IN-LINE POWER CHECKERb, f, i
Power range (dBm)–60 to 23
Power uncertainty (dB)g, h±0.5
Calibrated wavelengths (nm)1310, 1490, 1550, 1625, 1650
Selectable wavelengths (nm)1270, 1290, 1310, 1330, 1350, 1370, 1390, 1410, 1430, 1450, 1470, 1490, 1510, 1530, 1550, 1570, 1577, 1590, 1610, 1625, 1650
Tone detectionCW, 270 Hz, 330 Hz, 1 kHz, 2 kHz
BUILT-IN POWER METER SPECIFICATIONS (GeX) (optional)c
Calibrated wavelengths (nm)850, 1300, 1310, 1490, 1550, 1625, 1650
Selectable wavelenghts (nm)850, 1300, 1310, 1490, 1550, 1577, 1625, 1650
Power range (dBm)d27 to –50
Uncertainty (%)e±5 % ± 10 nW
Display resolution (dB)0.01 = max to –40 dBm
0.1 = –40 dBm to –50 dBm
Automatic offset nulling ranged, fMax power to –30 dBm
Tone detection (Hz)270/330/1000/2000
IN-LINE SOURCE
Output power (dBm)a–8
ModulationCW, 270 Hz, 330 Hz, 1 kHz, 2 kHz
VISUAL FAULT LOCATOR (VFL) (optional)
Laser650 nm ± 10 nm
CW/Modulate1 Hz
Typical Pout in 62.5/125 µm> –1.5 dBm (0.7 mW)
Laser safetyClass 2
a. All specifications valid at 23 °C ± 2 °C with an FC/APC connector, unless otherwise specified. b. Typical. c. Typical dynamic range with longest pulse and three-minute averaging at SNR = 1. d. Typical, for reflectance from –55 dB, using a 3-ns pulse. e. Does not include uncertainty due to fiber index. f. Not available when OPM2 is selected. g. At calibrated wavelengths. h. Requires a good entry connector’s health. i. Specifications valid when OTDR not in operation or in idle mode. a. Typical output power is given at 1550 nm. b. –20 °C to 60 °C (–4 °F to 140 °F) with the battery pack. c. At 23 ºC ± 1 ºC, 1550 nm and FC connector. With modules in idle mode. Battery operated after 20-minute warm-up. d. Typical. e. At calibration conditions. f. For ±0.05 dB, from 10 °C to 30 °C.
General specifications
Size (H × W × D)166 mm × 200 mm × 68 mm (6 9/16 in × 7 7/8 in × 2 3/4 in)
Weight (with battery)1.5 kg (3.3 lb)
TemperatureOperating
Storage
–10 °C to 50 °C (14 °F to 122 °F)
–40 °C to 70 °C (–40 °F to 158 °F)b
Relative humidity0 % to 95 % non-condensing
Warranty (year)1