FLS-600 NS-1548 - FLS-600-NS1548 - 环形通量(EF)测试解决方案

初级/中级解决方案,带可控的光源注入条件,提供非常高的精度和可重复性,旨在消除多模光纤测试的不确定性。

主要优点

依据TIA -526-14-B和IEC 61280-4-1 Ed. 2.0,满足EF要求
针对多模损耗测试进行了优化
按照TIA-568推荐方法,进行初级和终极多模光纤测试
参考级UPC连接器,提供非常高的精度和可重复性
符合EF要求的内置光源 ——不需要其它设备进行操作

应用

数据中心/高速链路
企业网和专用网

规格

技术规格
Auto-Wavelength Switching
Calibrated wavelengths 850/1300/1310/1550
Fiber Connector Type E2000/LC/SC/ST
Fiber Type Singlemode/Multimode
Product type Handheld
Test Type Fiber continuity/Link-loss characterization
Visual Fault Locator (VFL)
规格书

描述

Understanding encircled flux

Encircled Flux (EF) is a new standard that defines how to control the source launch conditions as specified in TIA-526-14-B and IEC 61280-4-1 Ed. 2.0.


Whether for an expanding enterprise business or a large-volume data center, the new high-speed data networks built with multimode fibers are running under tighter tolerances than ever before.


These multimode fibers are the trickiest links to test because the results depend greatly on each device’s output conditions. Testing with different equipment often returns different test results, sometimes higher than the budget loss itself. This may mislead the technician or make it impossibleto locate the fault, resulting in unsuccessful turnups or a longer network downtime. Now, cable installers can rely on their tier-1 loss results to perform tier-2 troubleshooting, and do so with maximum accuracy and utmost confidence of finding the actual problem.


Consistency and repeatability

Whether built-in or packaged in the external launch conditioner, EXFO tunes each EF-compliant device to perfection in-house, ensuring that every unit meets the EF templates for both 850 and 1300 nm at 50 μs. This allows technicians and contractors to obtain reliable, consistent and repeatable results during construction, thus eliminating doubts and uncertainty. The test documentation that is generated will also help future-proof networks. When upgrades are needed, technicians and contractors will know quickly which circuits have to be activated, thereby saving time and troubles down the line.


The necessity of launch and receive cables

Link characterization is often performed using an OTDR. However, despite the fact that an OTDR has the shortest dead zones, the way loss is measured in a link means that to characterize the first and last connectors, an OTDR needs a launch cable, also called a pulse suppressor box.


The reason for this is that the loss associated with an event is the difference between the backscattering levels measured before and after the event. To account for the dead zone, a backscattering level must be obtained before the first connector. This requires inserting a length of fiber between the OTDR port and the first connector of the fiber under test. At the other end, the same lengthof fiber is inserted after the last connector.


In order to measure the loss of the first and last connectors, it is important to use launch and receive cables. The SPSB-EF has an internal 30-meter fiber that allows complete end-to-end loss while still maintaining the EF launch conditions up to the first connector of the link. By complying with the EF standards, faulty connectors are easily located when troubleshooting high-speed multimode links.

规格书
环形通量(EF)测试解决方案 - English (2025年6月06日)
规格书
环形通量(EF)测试解决方案 - Français (2025年6月06日)
规格书
环形通量(EF)测试解决方案 - Deutsch (2025年6月06日)
规格书
环形通量(EF)测试解决方案 - 中文 (2025年6月06日)
应用说明
使用APC连接器优化OTDR/iOLM的长期性能 - English (2011年8月22日)
应用说明
使用APC连接器优化OTDR/iOLM的长期性能 - Français (2011年8月22日)
应用说明
使用APC连接器优化OTDR/iOLM的长期性能 - 中文 (2011年8月22日)
应用说明
使用APC连接器优化OTDR/iOLM的长期性能 - Español (2011年8月22日)
应用说明
使用APC连接器优化OTDR/iOLM的长期性能 - Deutsch (2011年8月22日)
现场培训
高级OTDR测试 - English (2012年1月05日)
现场培训
高级OTDR测试 - Français (2012年1月05日)
现场培训
高级OTDR测试 - 中文 (2012年1月05日)
手册和产品目录
OTDR和iOLM产品手册 - English (2019年5月20日)
手册和产品目录
OTDR和iOLM产品手册 - 中文 (2019年5月20日)
参考指南
Distributed Antenna System - English (2013年5月12日)
参考指南
FTTx PON指南 - English (2011年12月12日)
参考指南
FTTx PON指南 - 中文 (2011年12月12日)
参考指南
FTTx PON指南 - Español (2011年12月12日)
参考指南
FTTx PON指南 - Deutsch (2011年12月12日)
应用说明
Multimode Fiber Certification: Light Source Launch Conditions and Encircled Flux Standard - English (2011年8月21日)
应用说明
使用智能光链路测试仪(iOLM)来降低FTTH OPEX - English (2011年8月23日)
应用说明
使用智能光链路测试仪(iOLM)来降低FTTH OPEX - Français (2011年8月23日)
应用说明
使用智能光链路测试仪(iOLM)来降低FTTH OPEX - 中文 (2011年8月23日)
应用说明
使用智能光链路测试仪(iOLM)来降低FTTH OPEX - Español (2011年8月23日)
应用说明
使用智能光链路测试仪(iOLM)来降低FTTH OPEX - Deutsch (2011年8月23日)
应用说明
Touching on Failure: Sources of Fiber-Optic Network Issues in the Data Center - English (2016年2月08日)
多媒体培训
Web Training Series—FTB-1 and FTB-730-iOLM - English (2011年12月14日)

支持